PumpsAlso called: water pump, submersible well pump, deep well pump
Two numbers decide whether a power station runs a well pump, and readers arrive using them interchangeably. Watts are the ceiling on what the inverter can hold at any instant — this load needs 660 W of them while it runs, and 6,762 W for the moment it starts. Watt-hours are how much energy the battery holds. A machine can have plenty of one and not enough of the other.
Of the 26 machines in our library, 2 run it, 0 are a tight fit and 24 are out of reach. Each of those is a calculation against that machine’s continuous output, its surge ceiling and its inverter waveform — not a lookup table — and the reasoning is on every row.
The three numbers a power station is judged against
Running power660 W660–1,215 W Official spec · verified 2026-08-01 · high confidence
Start-up surge6,762 Wengine checks 6,762 W Official spec · verified 2026-08-01 · high confidence
Duty cycleNot published by the manufacturer no figure to date
The band is the spread across real models in this class, not a tolerance. Size against the top of it unless you know which unit you own.
The start-up figure is the manufacturer’s own locked-rotor rating, off a spec sheet for a real model in this class — not a category multiple. Where a standards table and the nameplate disagree, this library uses the nameplate: the standards figure is a selection envelope for breakers and controllers, and sizing a battery to it over-specifies the machine by two to four times.
This record publishes both an absolute inrush and a multiple of running power. They do not agree exactly, so the engine checks against the more demanding of the two — 6,762 W — rather than picking the flattering one.
Measured duration 500 ms · Official spec · verified 2026-08-01 · medium confidence
official · verified 2026-08-01 · appliance record
What actually decides it
A motor load: the first half-second decides it
An induction motor with a stationary rotor is close to a short circuit. For the fraction of a second before it turns, it pulls several times its running current, and that peak — not the running figure — is what trips an inverter. This is why a machine drawing well under a station’s continuous rating can still fail to start on it, and why the start-up figure at the top of this page matters more than the running one.
What kind of motor is inside
The motor is a plain induction motor, so the start-up figure is a locked-rotor current: the draw while the rotor is still stationary. It is over in well under a second, but an inverter has to survive all of it.
How long the start-up actually lasts
The inrush lasts a couple of tenths of a second, which is the window a station’s surge rating is written for. This is the one case where the surge figure and the surge ceiling are directly comparable.
Watts are not what the inverter is holding
At a power factor of 0.57 this load presents 1,158 VA to the inverter. An inverter is sold in watts and limited in volt-amps, so a machine that looks comfortable on the watt figure can be at its ceiling on the VA one. The engine checks both.
Which power stations run it
Every row is a live calculation against that machine's continuous output, surge ceiling and
inverter waveform. Of 26 machines, 2 run it, 0 are a tight fit and 24 are out of reach. The percentage is
this load as a share of that machine's continuous output; anything past 82% drops out of the green. Rows are ordered by verdict, then by
price — cheapest first inside each band.
EcoFlow DELTA Pro 3EcoFlow · US 120 V4,000 W continuous · 8,000 W surge ceiling17%
660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $2,399 · checked 2026-08-01 Show the working →
EcoFlow DELTA Pro 3EcoFlow · EU 230 V4,000 W continuous · 8,000 W surge ceiling17%
660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €3,299 · checked 2026-08-01 Show the working →
EcoFlow RIVER 3 PlusEcoFlow · US 120 V600 W continuous · 1,200 W surge ceiling110%
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $259 · checked 2026-08-01 Show the working →
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap.BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $299 · checked 2026-08-01 Show the working →
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $299.99 · checked 2026-08-01 Show the working →
BLUETTI Elite 100 V2BLUETTI · US 120 V1,800 W continuous · 3,600 W surge ceiling37%
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap. $499 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $499 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 PlusEcoFlow · US 120 V1,800 W continuous · 3,600 W surge ceiling37%
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $689 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $899 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 MaxEcoFlow · US 120 V2,400 W continuous · 4,800 W surge ceiling28%
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $949 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $999 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap.BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,099 · checked 2026-08-01 Show the working →
limited by VA ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,279 · checked 2026-08-01 Show the working →
Anker SOLIX C300Anker SOLIX · EU 230 V300 W continuous · 600 W surge ceiling220%
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €269.99 · checked 2026-08-01 Show the working →
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap.BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €279 · checked 2026-08-01 Show the working →
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €279 · checked 2026-08-01 Show the working →
EcoFlow RIVER 3 PlusEcoFlow · EU 230 V600 W continuous · 1,200 W surge ceiling110%
limited by continuous output 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €299 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €599 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap.BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €699 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €799 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 PlusEcoFlow · EU 230 V1,800 W continuous · 3,600 W surge ceiling37%
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €849 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.Anker SOLIX publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €999 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €999 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 MaxEcoFlow · EU 230 V2,400 W continuous · 4,800 W surge ceiling28%
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,199 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: we do not hold a duty cycle for this load, and no figure is estimated to fill the gap.BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €1,299 · checked 2026-08-01 Show the working →
limited by surge ceiling 660 Wh per hour — while it is actually runningNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,799 · checked 2026-08-01 Show the working →
The cheapest US 120 V machine in the list that runs a well pump outright, and it holds it at 660 Wh per hour.
$2,399 · price checked 2026-08-01
The buy link is in the bar at the bottom of the screen — one action per page, and it
goes to the merchant we last checked the price at.
Everything else we hold on this load
Each figure carries the tier it came from and the date it was checked. Sizing guidance is
kept apart from measured draw on purpose: one says what the machine pulls, the other says
what a manufacturer or a standard thinks you should buy for it.
Measured and published draw
Standby draw0 W Official spec · verified 2026-08-01 · medium confidence
Power factor0.57 Official spec · verified 2026-08-01 · medium confidence
The inverter is loaded to 1,158 VA — 660 W ÷ 0.57 — which is the figure its ceiling is actually measured against.
Sizing guidance — not a draw figure
Minimum continuous output1,150 W Official spec · verified 2026-08-01 · high confidence
A sizing figure, not a draw: it is what this class needs a machine to be RATED at, headroom included.
Minimum surge capability6,762 W Official spec · verified 2026-08-01 · high confidence
The start-up headroom this class needs an inverter to have. Where it comes from a manufacturer’s inverter recommendation rather than a measured inrush, it is deliberately generous.
A well pump has a guide of its own: the same records this page computes from, worked through in prose with room for the reasoning a table can only summarise — How do I power an off-grid shed or cabin?
Questions people ask about this load
How many watts does a well pump use?
660 W while it is running, and 660–1,215 W across the models in this class, with 6,762 W demanded at the instant it starts. Those are different questions and most pages answer only the first. The running figure decides whether a machine can hold it; the start-up figure decides whether it can get it going at all, and it is usually the one that fails. The start-up figure here is the manufacturer’s own..
What size power station do I need for a well pump?
For a well pump, the EcoFlow DELTA Pro 3 (US 120 V) is the cheapest machine in our library that runs it, at 4,000 W continuous · 8,000 W surge ceiling and $2,399 against a running draw of 660 W and a start-up demand of 6,762 W. That is a verdict computed from this load’s running watts, its start-up demand and the inverter waveform — not a rule of thumb about doubling the wattage. 2 of 26 machines clear it, 0 are a tight fit, and the tight ones are tight for reasons the list states individually.
How long will a power station run a well pump?
No machine in our library can answer that honestly yet, and none of the 26 rows above pretends otherwise. A runtime needs a usable-capacity figure; for the machines that reach a well pump the brands publish a nameplate watt-hour rating and nothing about depth of discharge or inverter efficiency. Dividing that nameplate by this load would give a confident-looking figure that is typically 20–35% too high. Every row gives the energy rate instead — watt-hours per hour — which needs no battery figure at all.
Why does a well pump need so much more power to start?
The start-up figure is the manufacturer’s own locked-rotor rating, off a spec sheet for a real model in this class — not a category multiple. Where a standards table and the nameplate disagree, this library uses the nameplate: the standards figure is a selection envelope for breakers and controllers, and sizing a battery to it over-specifies the machine by two to four times. The engine works the check against 6,762 W, which is what a station's surge ceiling has to cover for the moment the machine starts. A station whose continuous rating is comfortably above the running figure can still refuse the start, and that is the single most common way a purchase goes wrong for this class.
Which power stations run a well pump?
2 of the 26 we hold, listed above cheapest-first within each verdict band, starting with the EcoFlow DELTA Pro 3. 0 more are a tight fit on a well pump — they run it, but with less headroom than we are willing to call comfortable — and 24 cannot. Every one of those is a live calculation against that machine's own record, and opening a row shows the working.
2 of 26 machines run itEcoFlow DELTA Pro 3 · from $2,399