What will an EcoFlow DELTA Pro 3 run? (EU 230 V)

A “4,000 W” power station is two numbers wearing one label. Watts are the ceiling on what you can switch on at once; watt-hours are how much energy is in the battery. The EcoFlow DELTA Pro 3 holds 4,000 W and stores 4,096 Wh on the nameplate — and those two facts answer two different questions.

This page answers the first one. We have found no published depth of discharge or inverter efficiency for the EU 230 V build. Without one of the two there is no defensible usable-capacity figure, and this page will not turn the nameplate into hours.

The three numbers that decide everything else

Continuous output 4,000 W
Official spec · verified 2026-08-01 · high confidence
Surge ceiling 8,000 W
Official spec · verified 2026-08-01 · high confidence
Nominal capacity 4,096 Wh
Official spec · verified 2026-08-01 · high confidence

No usable-capacity figure for the EU 230 V build

EcoFlow states a nameplate watt-hour number for it, and we have found no published depth of discharge or inverter efficiency for the EU 230 V build. Dividing the nameplate by a load would be wrong by 20–35%, so this page shows the nameplate for what it is and refuses to turn it into hours.

Missing: station.usable_capacity_wh

Official specverified 2026-08-01EU 230 V unit

What EcoFlow DELTA Pro 3 runs

Every row is a live calculation against this machine's continuous output, surge ceiling and inverter waveform — running watts, start-up inrush and duty cycle on the appliance side. Of 38 appliance profiles, 28 run, 6 are a tight fit and 4 are out of reach. The percentage is the load as a share of continuous output; anything past 82% drops out of the green.

12V portable fridge/freezer Refrigeration 90 W running · 180 W at start-up Runs it2.3% Air fryer Cooking 1,700 W running · 1,700 W at start-up Runs it43% Aquarium air pump Pumps 3.5 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit0.1% Aquarium heater Heating 100 W running · 100 W at start-up Runs it2.5% Box fan Cooling 80 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit2.0% Chest freezer Refrigeration 30 W running · 156 W at start-up Runs it0.8% Coffee maker Cooking 1,400 W running · 1,400 W at start-up Runs it35% CPAP machine Medical 22 W running · 22 W at start-up Runs it0.5% Desktop PC Computing 13 W running · 13 W at start-up The measured inrush here is a millisecond-scale capacitive spike, which is not the same quantity as a surge rating and is not held against the verdict. Runs it0.3% Diesel air heater Heating 34 W running · 34 W at start-up Runs it0.9% Electric blanket Heating 60 W running · 60 W at start-up Runs it1.5% Electric kettle Cooking 3,000 W running · 3,000 W at start-up Runs it75% Electric space heater (1500 W) Heating 2,000 W running · 2,000 W at start-up Runs it50% Full-size refrigerator Refrigeration 55 W running · 286 W at start-up Runs it1.4% Gas furnace blower Heating 548 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit14% Hair dryer Personal care 2,100 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit53% Home oxygen concentrator Medical 312 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit7.8% Inverter window air conditioner (U-shaped) Cooling 667 W running · 667 W at start-up limited by mains standard Wrong mains Laptop computer Computing 5.2 W running · 5.2 W at start-up The measured inrush here is a millisecond-scale capacitive spike, which is not the same quantity as a surge rating and is not held against the verdict. Runs it0.1% LED light bulb Lighting 8.5 W running · 8.5 W at start-up Runs it0.2% LED TV TV & entertainment 108 W running · 108 W at start-up Runs it2.7% Microwave oven Cooking 1,480 W running limited by surge ceiling We hold no start-up surge figure for this appliance, so the verdict is capped below green — the running watts alone are comfortable. Tight fit37% Mini fridge Refrigeration 161 W running · 2,530 W at start-up Runs it4.0% Mini-split heat pump Cooling 1,740 W running · 1,740 W at start-up Runs it44% Pancake air compressor Power tools 1,800 W running · 10,800 W at start-up limited by surge ceiling Too big135% of surge ceiling Portable air conditioner Cooling 1,300 W running · 9,100 W at start-up limited by surge ceiling Too big114% of surge ceiling Portable induction cooktop Cooking 1,800 W running · 1,800 W at start-up Runs it45% Portable split air conditioner (hose-through-window) Cooling 1,500 W running · 1,500 W at start-up Runs it38% Router + modem Internet 9.1 W running · 9.1 W at start-up Runs it0.2% RV rooftop air conditioner RV & marine 1,690 W running · 8,619 W at start-up limited by surge ceiling Too big108% of surge ceiling Starlink Mini Internet 40 W running · 60 W at start-up Runs it1.0% Sump pump Pumps 720 W running · 2,645 W at start-up Runs it18% Variable-speed pool pump Pumps 627 W running · 627 W at start-up Runs it16% Video projector TV & entertainment 345 W running · 345 W at start-up Runs it8.6% Washing machine Laundry 2,300 W running · 2,300 W at start-up Runs it57% Welder (stick / MIG) Power tools 2,700 W running · 2,700 W at start-up Runs it68% Well pump Pumps 660 W running · 6,762 W at start-up Runs it17% Window air conditioner Cooling 833 W running · 6,900 W at start-up Runs it21%

Solar panels this machine can legally take

The binding constraint is voltage, not watts: open-circuit voltage RISES as it gets colder, and an array that is fine at noon can be over the MPPT ceiling at dawn. Each row is the engine's largest legal array for this station, with Voc corrected to -10 °C ambient . Only panels whose datasheet publishes a voltage temperature coefficient are evaluated — the others cannot be corrected, and an under-corrected array is what destroys an MPPT input.

Jackery SolarSaga 100 Air 12 × 100 W · 4S3P · 1200 W array Voc at the design minimum: 129.2 V Panel connector: DC8020 Needs a dc8mm-to-xt60 adapter.
Renogy 100W N-Type Monocrystalline Solar Panel 10 × 100 W · 5S2P · 1000 W array Voc at the design minimum: 124.3 V Panel connector: Solar Connectors We have found no published connector standard for it.
Renogy 200W N-Type Monocrystalline Solar Panel 6 × 200 W · 3S2P · 1200 W array Voc at the design minimum: 122.5 V Panel connector: Solar Connectors We have found no published connector standard for it.

Every field we hold on this machine

Each figure carries the tier it came from and the date it was checked. A blank is never left blank: a field we have found no figure for says so, and a field two manufacturer sources disagree about says that instead of picking one.

AC output

What the inverter can hold, what it can start, and what shape the wave is.

Continuous output 4,000 W Official spec · verified 2026-08-01 · high confidence
Surge ceiling 8,000 W Official spec · verified 2026-08-01 · high confidence
Surge duration Not found in the sources we checked no figure to date
Boost mode Yes Official spec · verified 2026-08-01 · high confidence

Sold as “X-Boost”.

Boost output 6,000 W Official spec · verified 2026-08-01 · high confidence

The verdict engine never counts boost output as continuous output: it works by dropping voltage and can fail on motors and compressors.

Inverter waveform Pure sine wave Official spec · verified 2026-08-01 · high confidence
Inverter efficiency Not found in the sources we checked no figure to date
AC voltage 230 V Official spec · verified 2026-08-01 · high confidence
AC frequency 50 Hz Official spec · verified 2026-08-01 · high confidence
Outlet standard Schuko Type F (CEE 7/3) + CEE 16A Official spec · verified 2026-08-01 · high confidence
UPS switchover 10 ms Official spec · verified 2026-08-01 · high confidence
Idle draw Not found in the sources we checked no figure to date

What the machine consumes just being switched on. It sits in the runtime denominator, and a record we hold no figure for makes every runtime optimistic.

Battery and energy

The nameplate, what is actually retrievable from it, and how long the cells last.

Nominal capacity 4,096 Wh Official spec · verified 2026-08-01 · high confidence
Usable capacity Not found in the sources we checked no figure to date

Not on record, and not derivable: we have found no published depth of discharge or inverter efficiency for the EU 230 V build.

Depth of discharge Not found in the sources we checked no figure to date
Chemistry LiFePO4 (LFP) Official spec · verified 2026-08-01 · high confidence
Cycle life 4,000 cycles Official spec · verified 2026-08-01 · high confidence
Capacity at end of cycle life 80% Official spec · verified 2026-08-01 · high confidence
Warranty Not found in the sources we checked no figure to date
Discharge temperature (min) -10 °C Official spec · verified 2026-08-01 · high confidence
Discharge temperature (max) 45 °C Official spec · verified 2026-08-01 · high confidence
Charge temperature (min) 0 °C Official spec · verified 2026-08-01 · high confidence

Charging and expansion

How fast it refills from the wall, and whether more battery can be bolted on.

AC input (max) 2,900 W Official spec · verified 2026-08-01 · high confidence
Wall charge, 0–100% Not found in the sources we checked no figure to date
Wall charge, 0–80% Not found in the sources we checked no figure to date
Car input (max) Not found in the sources we checked no figure to date
Combined input (max) Not found in the sources we checked no figure to date
Expandable Yes Official spec · verified 2026-08-01 · high confidence
Capacity with expansion 12,000 Wh Official spec · verified 2026-08-01 · medium confidence
Extra batteries supported 2 Official spec · verified 2026-08-01 · high confidence

Solar input

The window an array has to land inside. Voltage is the constraint that burns hardware.

Solar input (max) 2,600 W Official spec · verified 2026-08-01 · high confidence
MPPT window (min) 11 V Official spec · verified 2026-08-01 · high confidence
MPPT window (max) 150 V Official spec · verified 2026-08-01 · high confidence
Input current (max) 20 A Official spec · verified 2026-08-01 · high confidence
Solar connector XT60 (High-PV) / XT60i (Low-PV) Official spec · verified 2026-08-01 · high confidence

Physical and travel

Weight, size, noise — and whether an airline will let it on board.

Weight 51.5 kg Official spec · verified 2026-08-01 · high confidence
Length 693 mm Official spec · verified 2026-08-01 · high confidence
Width 410 mm Official spec · verified 2026-08-01 · high confidence
Height 341 mm Official spec · verified 2026-08-01 · high confidence
Noise Not found in the sources we checked no figure to date
App control Yes Official spec · verified 2026-08-01 · high confidence
Connectivity Wi-Fi, Bluetooth, can Official spec · verified 2026-08-01 · high confidence
Capacity for airline rules 4,096 Wh Official spec · verified 2026-08-01 · high confidence

IATA lets passengers carry lithium batteries up to 100 Wh freely and 100–160 Wh with airline approval. Above that, no passenger aircraft.

Where to buy

Where to buy the EcoFlow DELTA Pro 3

Prices checked 2026-08-17

EcoFlow Official Store (EU) €3,299 View →

Compare with its neighbours

Each link goes to that machine's own record. Every record holds the same fields in the same order and states the same tier and date beside each one, so two of them read side by side compare cleanly.

Where to go next

Questions people ask about this machine

Will an EcoFlow DELTA Pro 3 run a full-size refrigerator?
Yes. Against the EU 230 V record, the full-size refrigerator draws 55 W running · 286 W at start-up — 1.4% of this machine's continuous output. That verdict is a calculation from running watts, start-up surge and inverter waveform, not a lookup, and the full working is one click away in the table above.
Why can't an EcoFlow DELTA Pro 3 run an inverter window air conditioner (U-shaped)?
On the EU 230 V record the binding constraint is the mains standard, so nothing about this machine's capacity enters into it. The inverter window air conditioner (U-shaped) draws 667 W running · 667 W at start-up, and a larger machine on the same output voltage would fail in exactly the same way. What has to change is the output voltage, not the size of the machine.
How long will an EcoFlow DELTA Pro 3 run my appliances?
We will not put a number on it, and that is deliberate. A runtime needs a usable-capacity figure, and we have found no published depth of discharge or inverter efficiency for the EU 230 V build — only a nameplate watt-hour rating. Dividing that nameplate by your load produces a confident-looking figure that is typically 20–35% too high. What this page gives you instead is every load's energy rate in watt-hours per hour, which needs no battery figure at all and is the number you actually size against.
Can you take an EcoFlow DELTA Pro 3 on a plane?
No. At 4,096 Wh it is far above the 160 Wh ceiling that airlines apply to lithium batteries in the cabin, and lithium batteries of this size are not accepted in checked baggage either. The 100 Wh / 160 Wh thresholds come from the IATA dangerous-goods rules that carriers implement; check your airline before travelling, because the approval step above 100 Wh is theirs to give.
Is the EU EcoFlow DELTA Pro 3 the same as the US one?
No, and we keep them as two separate records for that reason. This one is built for 230 V mains and the US version for 120 V, which changes the outlets, the certifications and the charging figures. Where the brand publishes different numbers for the two, this page shows only the ones for the EU 230 V version.
Back to top ↑

Runs 28 of 38 test loads EcoFlow DELTA Pro 3 · from €3,299

Check price →