CoolingAlso called: portable ac, portable ac unit, rolling air conditioner
Two numbers decide whether a power station runs a portable air conditioner, and readers arrive using them interchangeably. Watts are the ceiling on what the inverter can hold at any instant — this load needs 1,300 W of them while it runs, and 7,800 W for the moment it starts. Watt-hours are how much energy the battery holds. A machine can have plenty of one and not enough of the other.
Nothing in our library of 26 machines runs it outright. That is the answer, and the list below shows how close each one gets and which constraint stops it — every verdict is a calculation against that machine’s continuous output, its surge ceiling and its inverter waveform, not a lookup table.
The three numbers a power station is judged against
Running power1,300 W Official spec · verified 2026-08-01 · high confidence
Start-up surge6,900 Wengine checks 7,800 W Official spec · verified 2026-08-01 · medium confidence
Duty cycle18% Official spec · verified 2026-08-01 · high confidence
The start-up figure is the manufacturer’s own locked-rotor rating, off a spec sheet for a real model in this class — not a category multiple. Where a standards table and the nameplate disagree, this library uses the nameplate: the standards figure is a selection envelope for breakers and controllers, and sizing a battery to it over-specifies the machine by two to four times.
This record publishes both an absolute inrush and a multiple of running power. They do not agree exactly, so the engine checks against the more demanding of the two — 7,800 W — rather than picking the flattering one.
Measured duration 200 ms · Official spec · verified 2026-08-01 · low confidence
Two ways to read a duty cycle
A duty cycle can be read two ways and they are not the same number. One is the constant a test procedure assumes so that a label figure is reproducible; the other is what the machine does in a real room, which depends on the weather, the door and the thermostat. This record keeps both ends: 12% to 90%, with the default above. The named readings below each carry their own source and date, so you can see which one a figure came from rather than being handed a blend of the two.
Residential, outdoor 83°F 12% Official spec · verified 2026-08-01
Residential, outdoor 95°F default18% Official spec · verified 2026-08-01
Continuous use, outdoor 95°F 90% Official spec · verified 2026-08-01
official · verified 2026-08-01 · appliance record
What actually decides it
A motor load: the first half-second decides it
An induction motor with a stationary rotor is close to a short circuit. For the fraction of a second before it turns, it pulls several times its running current, and that peak — not the running figure — is what trips an inverter. This is why a machine drawing well under a station’s continuous rating can still fail to start on it, and why the start-up figure at the top of this page matters more than the running one.
How long the start-up actually lasts
The inrush lasts a couple of tenths of a second, which is the window a station’s surge rating is written for. This is the one case where the surge figure and the surge ceiling are directly comparable.
Watts are not what the inverter is holding
At a power factor of 0.97 this load presents 1,340 VA to the inverter. An inverter is sold in watts and limited in volt-amps, so a machine that looks comfortable on the watt figure can be at its ceiling on the VA one. The engine checks both.
Which power stations run it
Every row is a live calculation against that machine's continuous output, surge ceiling and
inverter waveform. Of 26 machines, 0 run it, 2 are a tight fit and 24 are out of reach. The percentage is
this load as a share of that machine's continuous output; anything past 82% drops out of the green. Rows are ordered by verdict, then by
price — cheapest first inside each band.
EcoFlow DELTA Pro 3EcoFlow · US 120 V4,000 W continuous · 8,000 W surge ceiling33%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $2,399 · checked 2026-08-01 Show the working →
EcoFlow DELTA Pro 3EcoFlow · EU 230 V4,000 W continuous · 8,000 W surge ceiling33%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €3,299 · checked 2026-08-01 Show the working →
EcoFlow RIVER 3 PlusEcoFlow · US 120 V600 W continuous · 1,200 W surge ceiling217%
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $259 · checked 2026-08-01 Show the working →
limited by continuous output 1.0 h — on a full charge, with the station’s own 9.0 W idle draw in the denominatorBLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $299 · checked 2026-08-01 Show the working →
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $299.99 · checked 2026-08-01 Show the working →
BLUETTI Elite 100 V2BLUETTI · US 120 V1,800 W continuous · 3,600 W surge ceiling72%
limited by surge ceiling 3.4 h — on a full charge, with the station’s own 10 W idle draw in the denominator $499 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $499 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 PlusEcoFlow · US 120 V1,800 W continuous · 3,600 W surge ceiling72%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $689 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $899 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 MaxEcoFlow · US 120 V2,400 W continuous · 4,800 W surge ceiling54%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $949 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $999 · checked 2026-08-01 Show the working →
limited by surge ceiling 6.5 h — on a full charge, with the station’s own 10 W idle draw in the denominatorBLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,099 · checked 2026-08-01 Show the working →
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,279 · checked 2026-08-01 Show the working →
Anker SOLIX C300Anker SOLIX · EU 230 V300 W continuous · 600 W surge ceiling433%
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €269.99 · checked 2026-08-01 Show the working →
limited by continuous output 1.0 h — on a full charge, with the station’s own 9.0 W idle draw in the denominatorBLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €279 · checked 2026-08-01 Show the working →
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €279 · checked 2026-08-01 Show the working →
EcoFlow RIVER 3 PlusEcoFlow · EU 230 V600 W continuous · 1,200 W surge ceiling217%
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €299 · checked 2026-08-01 Show the working →
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €599 · checked 2026-08-01 Show the working →
limited by surge ceiling 3.4 h — on a full charge, with the station’s own 10 W idle draw in the denominatorBLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €699 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €799 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 PlusEcoFlow · EU 230 V1,800 W continuous · 3,600 W surge ceiling72%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €849 · checked 2026-08-01 Show the working →
limited by continuous output 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide.Anker SOLIX publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €999 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €999 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 MaxEcoFlow · EU 230 V2,400 W continuous · 4,800 W surge ceiling54%
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,199 · checked 2026-08-01 Show the working →
limited by surge ceiling 7.2 h — on a full charge, with the station’s own 13 W idle draw in the denominatorBLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €1,299 · checked 2026-08-01 Show the working →
limited by surge ceiling 234 Wh per hour — averaged over this load’s duty cycleNo runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,799 · checked 2026-08-01 Show the working →
Nothing we hold runs a portable air conditioner with room to spare. This is the cheapest that gets there at all, and the surge ceiling is what keeps it out of the green.
$2,399 · price checked 2026-08-01
The buy link is in the bar at the bottom of the screen — one action per page, and it
goes to the merchant we last checked the price at.
What changes the numbers
At 28.3 °C ambient×0.7Applied to how OFTEN it runs, not to how hard it pulls while running. The verdict does not move; the energy it costs you over a day does. Official spec
At 35 °C ambient×1Applied to how OFTEN it runs, not to how hard it pulls while running. The verdict does not move; the energy it costs you over a day does. Official spec
Between the anchorsOnly the anchor points above have a source. This site does not interpolate between them: a curve drawn through two published points is a number we invented, and it would arrive on the page wearing the same official label as the points it was drawn from.
Mains standards on recordUS 120 V · EU 230 VThe figures above are recorded per mains standard, because the same appliance class is built differently on 120 V and 230 V. Where only one standard is on record, the ranking still lists machines from both regions — each row states its own.
Everything else we hold on this load
Each figure carries the tier it came from and the date it was checked. Sizing guidance is
kept apart from measured draw on purpose: one says what the machine pulls, the other says
what a manufacturer or a standard thinks you should buy for it.
Measured and published draw
Power factor0.97 Official spec · verified 2026-08-01 · low confidence
The inverter is loaded to 1,340 VA — 1,300 W ÷ 0.97 — which is the figure its ceiling is actually measured against.
Sizing guidance — not a draw figure
Minimum continuous output1,300 W Official spec · verified 2026-08-01 · high confidence
A sizing figure, not a draw: it is what this class needs a machine to be RATED at, headroom included.
How many watts does a portable air conditioner use?
1,300 W while it is running, with 7,800 W demanded at the instant it starts. Those are different questions and most pages answer only the first. The running figure decides whether a machine can hold it; the start-up figure decides whether it can get it going at all, and it is usually the one that fails. The start-up figure here is the manufacturer’s own..
What size power station do I need for a portable air conditioner?
Bigger than anything in our library, on today's data. All 26 machines we hold were run against a portable air conditioner at 1,300 W running and 7,800 W at the start, and none of them clears it: 2 get there but only just, and 24 are short outright. The list above names the constraint that stops each one, which is the useful part — if it is the surge ceiling, a bigger battery on the same inverter rating will not help you.
How long will a power station run a portable air conditioner?
It depends entirely on the machine, which is the part most pages skip. Against 1,300 W of running draw, our figures put the BLUETTI Elite 30 V2 at about 1.0 h, and the BLUETTI Elite 100 V2 at about 3.4 h. Those hours come from usable-capacity figures derived from the manufacturers’ own published depth of discharge and inverter efficiency, with each machine’s idle draw in the denominator — not from dividing a nameplate watt-hour number by a label wattage. Most machines in the list carry no hours at all: their brands publish nothing that makes a usable-capacity figure defensible, so those rows give an energy rate instead of a number we would have had to invent.
Why does a portable air conditioner need so much more power to start?
The start-up figure is the manufacturer’s own locked-rotor rating, off a spec sheet for a real model in this class — not a category multiple. Where a standards table and the nameplate disagree, this library uses the nameplate: the standards figure is a selection envelope for breakers and controllers, and sizing a battery to it over-specifies the machine by two to four times. The engine works the check against 7,800 W, which is what a station's surge ceiling has to cover for the moment the machine starts. A station whose continuous rating is comfortably above the running figure can still refuse the start, and that is the single most common way a purchase goes wrong for this class.
Does a portable air conditioner draw that continuously?
No, and the difference is most of the energy question. This record holds more than one duty-cycle reading, each with its own source: Residential, outdoor 83°F at 12%, Residential, outdoor 95°F at 18%, Continuous use, outdoor 95°F at 90%. The one a page picks silently is the one that decides whether your battery lasts the night, so this site names them and lets you choose in the calculator rather than blending them into a single average.
0 of 26 machines run itEcoFlow DELTA Pro 3 · from $2,399