What size power station for a 12V fridge?

Refrigeration Also called: 12v fridge, portable fridge, camping fridge

Two numbers decide whether a power station runs a 12V portable fridge/freezer, and readers arrive using them interchangeably. Watts are the ceiling on what the inverter can hold at any instant — this load needs 90 W of them while it runs, and 180 W for the moment it starts. Watt-hours are how much energy the battery holds, and this load gets through about 222 Wh in a day. A machine can have plenty of one and not enough of the other.

Of the 26 machines in our library, 26 run it, 0 are a tight fit and 0 are out of reach. Each of those is a calculation against that machine’s continuous output, its surge ceiling and its inverter waveform — not a lookup table — and the reasoning is on every row.

The three numbers a power station is judged against

Running power 90 W 78–125 W Official spec · verified 2026-08-01 · high confidence
Start-up surge 180 W engine checks 180 W Official spec · verified 2026-08-01 · medium confidence
Duty cycle Not published by the manufacturer no figure to date

The band is the spread across real models in this class, not a tolerance. Size against the top of it unless you know which unit you own.

Start-up figure: Manufacturer-stated

The start-up figure is published by the manufacturer for this device, so it describes the actual hardware rather than a category.

This record publishes both an absolute inrush and a multiple of running power. They do not agree exactly, so the engine checks against the more demanding of the two — 180 W — rather than picking the flattering one.

officialverified 2026-08-01appliance record

What actually decides it

A variable-speed motor: it ramps instead of slamming

This compressor is fed by its own electronics, which start it gently and then modulate its speed to the work in front of it. The start-up peak is small or absent, and the running draw is a band rather than a point — low most of the time, climbing only under load. The binding constraint is usually the top of that band, not the start.

What kind of motor is inside

The motor is brushless and driven by its own inverter board, which is why the start-up demand is modest: the electronics ramp the motor rather than connecting it straight to the line.

Which power stations run it

Every row is a live calculation against that machine's continuous output, surge ceiling and inverter waveform. Of 26 machines, 26 run it, 0 are a tight fit and 0 are out of reach. The percentage is this load as a share of that machine's continuous output; anything past 82% drops out of the green. Rows are ordered by verdict, then by price — cheapest first inside each band.

EcoFlow RIVER 3 Plus EcoFlow · US 120 V 600 W continuous · 1,200 W surge ceiling 21%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $259 · checked 2026-08-01 Show the working →
BLUETTI Elite 30 V2 BLUETTI · US 120 V 600 W continuous 21%
1.8–2.8 h — on a full charge, with the station’s own 9.0 W idle draw in the denominator BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $299 · checked 2026-08-01 Show the working →
Jackery Explorer 300 Plus Jackery · US 120 V 300 W continuous · 600 W surge ceiling 42%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $299.99 · checked 2026-08-01 Show the working →
BLUETTI Elite 100 V2 BLUETTI · US 120 V 1,800 W continuous · 3,600 W surge ceiling 6.9%
6.1–9.4 h — on a full charge, with the station’s own 10 W idle draw in the denominator $499 · checked 2026-08-01 Show the working →
Jackery Explorer 1000 v2 Jackery · US 120 V 1,500 W continuous · 3,000 W surge ceiling 8.3%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $499 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 Plus EcoFlow · US 120 V 1,800 W continuous · 3,600 W surge ceiling 6.9%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $689 · checked 2026-08-01 Show the working →
Jackery Explorer 2000 Plus Jackery · US 120 V 3,000 W continuous · 6,000 W surge ceiling 4.2%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $899 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 Max EcoFlow · US 120 V 2,400 W continuous · 4,800 W surge ceiling 5.2%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $949 · checked 2026-08-01 Show the working →
Jackery Explorer 1000 Plus Jackery · US 120 V 2,000 W continuous · 4,000 W surge ceiling 6.3%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $999 · checked 2026-08-01 Show the working →
BLUETTI Elite 200 V2 BLUETTI · US 120 V 2,600 W continuous 4.8%
12–18 h — on a full charge, with the station’s own 10 W idle draw in the denominator BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,099 · checked 2026-08-01 Show the working →
EcoFlow STREAM Ultra EcoFlow · US 120 V 800 W continuous 16%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. $1,279 · checked 2026-08-01 Show the working →
EcoFlow DELTA Pro 3 EcoFlow · US 120 V 4,000 W continuous · 8,000 W surge ceiling 3.1%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. $2,399 · checked 2026-08-01 Show the working →
Anker SOLIX C300 Anker SOLIX · EU 230 V 300 W continuous · 600 W surge ceiling 42%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €269.99 · checked 2026-08-01 Show the working →
BLUETTI Elite 30 V2 BLUETTI · EU 230 V 600 W continuous 21%
1.8–2.8 h — on a full charge, with the station’s own 9.0 W idle draw in the denominator BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €279 · checked 2026-08-01 Show the working →
Jackery Explorer 300 Plus Jackery · EU 230 V 300 W continuous · 600 W surge ceiling 42%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €279 · checked 2026-08-01 Show the working →
EcoFlow RIVER 3 Plus EcoFlow · EU 230 V 600 W continuous · 1,200 W surge ceiling 21%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €299 · checked 2026-08-01 Show the working →
EcoFlow STREAM Ultra EcoFlow · EU 1,200 W continuous 10%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. EcoFlow publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €599 · checked 2026-08-01 Show the working →
BLUETTI Elite 100 V2 BLUETTI · EU 230 V 1,800 W continuous 6.9%
6.1–9.4 h — on a full charge, with the station’s own 10 W idle draw in the denominator BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €699 · checked 2026-08-01 Show the working →
Jackery Explorer 1000 v2 Jackery · EU 230 V 1,500 W continuous · 3,000 W surge ceiling 8.3%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €799 · checked 2026-08-01 Show the working →
EcoFlow DELTA 3 Plus EcoFlow · EU 230 V 1,800 W continuous · 3,600 W surge ceiling 6.9%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €849 · checked 2026-08-01 Show the working →
Anker SOLIX Solarbank 3 E2700 Pro Anker SOLIX · EU 1,200 W continuous 10%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Anker SOLIX publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. Anker SOLIX publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €999 · checked 2026-08-01 Show the working →
Jackery Explorer 1000 Plus Jackery · EU 230 V 2,000 W continuous · 4,000 W surge ceiling 6.3%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €999 · checked 2026-08-01 Show the working →
EcoFlow DELTA 2 Max EcoFlow · EU 230 V 2,400 W continuous · 4,800 W surge ceiling 5.2%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,199 · checked 2026-08-01 Show the working →
BLUETTI Elite 200 V2 BLUETTI · EU 230 V 2,600 W continuous 4.8%
13–19 h — on a full charge, with the station’s own 13 W idle draw in the denominator BLUETTI publishes no surge rating for this model. The start-up check runs against its continuous output as a conservative floor, which is ours, not a manufacturer specification. €1,299 · checked 2026-08-01 Show the working →
Jackery Explorer 2000 Plus Jackery · EU 230 V 3,000 W continuous · 6,000 W surge ceiling 4.2%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: Jackery publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €1,799 · checked 2026-08-01 Show the working →
EcoFlow DELTA Pro 3 EcoFlow · EU 230 V 4,000 W continuous · 8,000 W surge ceiling 3.1%
90 Wh per hour — averaged over this load’s duty cycle No runtime in hours: EcoFlow publishes no depth of discharge or inverter efficiency for this model, so there is no defensible usable-capacity figure to divide. €3,299 · checked 2026-08-01 Show the working →

Our pick for this load

EcoFlow RIVER 3 Plus · US 120 V

The cheapest US 120 V machine in the list that runs a 12V portable fridge/freezer outright, and it holds it at 90 Wh per hour.

$259 · price checked 2026-08-01

The buy link is in the bar at the bottom of the screen — one action per page, and it goes to the merchant we last checked the price at.

What changes the numbers

At 32 °C ambient ×1 Applied to the draw itself, which means the verdict can move with the weather. Official spec

Everything else we hold on this load

Each figure carries the tier it came from and the date it was checked. Sizing guidance is kept apart from measured draw on purpose: one says what the machine pulls, the other says what a manufacturer or a standard thinks you should buy for it.

Measured and published draw

Energy per year 81 kWh Official spec · verified 2026-08-01 · high confidence

Published on the EU energy label.

Energy per day 222 Wh Official spec · verified 2026-08-01 · medium confidence

Published on the EU energy label.

Sizing guidance — not a draw figure

Minimum continuous output 125 W Official spec · verified 2026-08-01 · high confidence

A sizing figure, not a draw: it is what this class needs a machine to be RATED at, headroom included.

Minimum surge capability 180 W Official spec · verified 2026-08-01 · medium confidence

The start-up headroom this class needs an inverter to have. Where it comes from a manufacturer’s inverter recommendation rather than a measured inrush, it is deliberately generous.

Usable energy for a full day 304 Wh Official spec · verified 2026-08-01 · medium confidence

Where to go next

From the Knowledge channel

A 12V portable fridge/freezer has a guide of its own: the same records this page computes from, worked through in prose with room for the reasoning a table can only summarise — Why does my power station shut off when the pump or fridge starts?

Questions people ask about this load

How many watts does a 12V portable fridge/freezer use?
90 W while it is running, and 78–125 W across the models in this class, with 180 W demanded at the instant it starts. Those are different questions and most pages answer only the first. The running figure decides whether a machine can hold it; the start-up figure decides whether it can get it going at all, and it is usually the one that fails. The start-up figure here is the manufacturer’s own..
What size power station do I need for a 12V portable fridge/freezer?
For a 12V portable fridge/freezer, the EcoFlow RIVER 3 Plus (US 120 V) is the cheapest machine in our library that runs it, at 600 W continuous · 1,200 W surge ceiling and $259 against a running draw of 90 W and a start-up demand of 180 W. That is a verdict computed from this load’s running watts, its start-up demand and the inverter waveform — not a rule of thumb about doubling the wattage. 26 of 26 machines clear it, 0 are a tight fit, and the tight ones are tight for reasons the list states individually.
How long will a power station run a 12V portable fridge/freezer?
It depends entirely on the machine, which is the part most pages skip. Against 90 W of running draw, our figures put the BLUETTI Elite 30 V2 at about 1.8–2.8 h, and the BLUETTI Elite 100 V2 at about 6.1–9.4 h. Those hours come from usable-capacity figures derived from the manufacturers’ own published depth of discharge and inverter efficiency, with each machine’s idle draw in the denominator — not from dividing a nameplate watt-hour number by a label wattage. Most machines in the list carry no hours at all: their brands publish nothing that makes a usable-capacity figure defensible, so those rows give an energy rate instead of a number we would have had to invent.
Why does a 12V portable fridge/freezer need so much more power to start?
The start-up figure is published by the manufacturer for this device, so it describes the actual hardware rather than a category. The engine works the check against 180 W, which is what a station's surge ceiling has to cover for the moment the machine starts. A station whose continuous rating is comfortably above the running figure can still refuse the start, and that is the single most common way a purchase goes wrong for this class.
Which power stations run a 12V portable fridge/freezer?
26 of the 26 we hold, listed above cheapest-first within each verdict band, starting with the EcoFlow RIVER 3 Plus. 0 more are a tight fit on a 12V portable fridge/freezer — they run it, but with less headroom than we are willing to call comfortable — and 0 cannot. Every one of those is a live calculation against that machine's own record, and opening a row shows the working.

26 of 26 machines run it EcoFlow RIVER 3 Plus · from $259

Check price →